Sentinel Diagnostics Laboratory

Sentinel Diagnostics Laboratory division comprehends the following product lines: Molecular Biology, Clinical Chemistry, Dedicated Reagents, FIT Systems (Fecal Immunochemical Test), Haemostasis, Immunology.

Each line includes a complete range of products aimed at satisfying the needs of medical analysis laboratories.

 

Turbidimetry
Ref. Product Quantity Method Docs.
1104001 Apo A-I 50 mL (1x40+1x10)
Immuno-turbidimetric determination of Apolipoprotein A-I - The kit contains specific anti Apolipoprotein A-I polyclonal antiserum (1x10 mL) liquid ready to use and reaction buffer (1x40 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent 1/Solution 2: 1/45/5 - Wavelength 340 nm - The Calibrator (REF 1120201) and the Control (REF 34Q021) are available separately - Measuring range: 16-350 mg/dL.
(1x40 + 1x10) 50 mL mL Turbidimetry
11003N Albumin 77 mL (1x66+1x11)
Immuno-turbidimetric determination of human Albumin in urine - The kit contains specific anti Albumin polyclonal antiserum (1x11 mL) and reaction buffer (1x66 mL) in dedicated vials for automation - Ratio: Urine/Reagent 1/Reagent 2: 1/30/3.3 - Wavelength 340 nm - The Calibrator (urine: REF 11207A) and the Controls (urine: REF 125001** microAlbumin 2 level Set) are available separately - Measuring range: Urine 0.4-500 mg/dL. Applications on serum/plasma for the most common analyzers are available. **REF 125001 microAlbumin Control 2 level Set: Urine based - 2 levels with values for microAlbumin in urine - Manufactured by Quantimetrix Corp., CA - USA (available directly or from the local authorized distributor).
1x66; 1x11 mL Turbidimetry
11135D alpha 1-Acid Glycoprotein 108 mL (2x50 + 2x4)
Immuno-turbidimetric determination of alpha 1-Acid Glycoprotein - The kit contains specific anti alpha 1-Acid Glycoprotein polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/18/2 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 20-600 mg/dL.
2x50; 2x4 mL Turbidimetry
11062D C4 108 mL (2x50+2x4)
Immuno-turbidimetric determination of C4 factor - The kit contains specific anti C4 polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/4.5/0.5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 5-200 mg/dL.
2x50; 2x4 mL Turbidimetry
11050D Haptoglobin 108 mL (2x50+2x4)
Immuno-turbidimetric determination of Haptoglobin - The kit contains specific anti Haptoglobin polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/18/2 - Wavelength 340 nm - The Calibrators (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 35-700 mg/dL.
2x50; 2x4 mL Turbidimetry
11100D IgA 108 mL (2x50+2x4)
Immuno-turbidimetric determination of human IgA - The kit contains specific anti IgA polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/18/2 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 20-1600 mg/dL.
2x50; 2x4 mL Turbidimetry
11102D IgG 108 mL (2x50+2x4)
Immuno-turbidimetric determination of IgG - The kit contains specific anti IgG polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/45/5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 200-7000 mg/dL.
2x50; 2x4 mL Turbidimetry
11106D IgM 108 mL (2x50+2x4)
Immuno-turbidimetric determination of IgM - The kit contains specific anti IgM polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/4.5/0.5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 20-700 mg/dL.
2x50; 2x4 mL Turbidimetry
11130D Transferrin 108 mL (2x50+2x4)
Immuno-turbidimetric determination of Transferrin - The kit contains specific anti Transferrin polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/45/5 - Wavelength 340 nm - The Calibrator ((REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 100-1800 mg/dL.
2x50; 2x4 mL Turbidimetry
1104201 Apo B 90 mL (2x40+1x10)
Immuno-turbidimetric determination of Apolipoprotein B - The kit contains specific anti Apolipoprotein B polyclonal antiserum (1x10 mL) liquid ready to use and reaction buffer (2x40 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent 1/Solution 2: 1/9/1 - Wavelength 340 nm – The Calibrator (REF 1120201) and the Control (REF 34Q021) are available separately - Measuring range: 13-800 mg/dL.
(2x40; 1x10) 90 mL mL Turbidimetry
11012N alpha 1-Antitrypsin 108 mL (2x50 + 1x8)
Immuno-turbidimetric determination of human alpha 1-Antitrypsin - The kit contains specific anti-alpha 1-Antitrypsin polyclonal antiserum (1x8 mL) liquid ready to use, reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Reagent B 1/45/5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 45-900 mg/dL.
2x50; 1x8 mL Colorimetric
11018D alpha-2 Macroglobulin 108 mL (2x50+2x4)
Immuno-turbidimetric determination of alpha 2-macroglobulin - The kit contains specific anti alpha 2-macroglobulin polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/9/1 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 70-1500 mg/dL.
(2x50; 2x4) 108 mL Turbidimetry
11030D Antithrombin III 106 mL (2x50+2x3)
Immuno-turbidimetric determination of human Antithrombin III - The kit contains specific anti Antithrombin III polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/9/1 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 5 -120 mg/dL.
(2x50; 2x3) 106 mL Turbidimetry
11040D Apolipoprotein A-1 108 mL (2x50 + 2x4)
Immuno-turbidimetric determination of Apolipoprotein A-1 - The kit contains specific anti Apolipoprotein A-1 polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/45/5 - Wavelength 340 nm - The Calibrator (REF 1120201) and the Controls (REF 34Q021) are available separately - Measuring range: 30-270 mg/dL.
(2x50; 2x4) 108 mL Turbidimetry
11042D Apolipoprotein B 108 mL (2x50 +2x4)
Immuno-turbidimetric determination of Apolipoprotein B - The kit contains specific anti Apolipoprotein B polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/9/1 - Wavelength 340 nm - The Calibrator (REF 1120201) and the Control (REF 34Q021) are available separately - Measuring range: 40-800 mg/dL.
(2x50; 2x4) 108 mL Turbidimetry
11052D C1 Esterase Inhibitor 108 mL (2x50+2x4)
Immuno-turbidimetric determination of C1 Esterase Inhibitor - The kit contains specific anti C1 Esterase Inhibitor polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/18/2 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 5-120 mg/dL.
(2x50; 2x4) 108 mL Turbidimetry
11060D C3 108 mL (2x50+2x4)
Immuno-turbidimetric determination of C3 factor - The kit contains specific anti C3 polyclonal antiserum (2x1mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/9/1 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 20-500 mg/dL.
2x50; 2x4 mL Turbidimetry
11065N Ceruloplasmin 108 mL (2x50+1x8)
Immuno-turbidimetric determination of Ceruloplasmin - The kit contains specific anti Ceruloplasmin polyclonal antiserum (1x8 mL) liquid ready to use, reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Sample/Reagent A/Reagent B: 1/100/12.5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 5-90 mg/dL.
(2x50; 1x8) 108 mL Turbidimetry
11004D Kappa light chains 120 mL (2x50 + 2x10)
Immuno-turbidimetric determination of Kappa light chains - The kit contains: reaction buffer (2x50 mL) in dedicated vials for automation and a specific anti Kappa light chains polyclonal antiserum (2x10 mL) - Ratio: Dil.Sample/Reagent A/Reagent B: 1/35/7.5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 70-1600 mg/dL.
(2x50; 2x10) 120 mL Turbidimetry
11005D Lambda light chains 120 mL (2x50 + 2x10)
Immuno-turbidimetric determination of Lambda light chains - The kit contains: reaction buffer (2x50 mL) in dedicated vials for automation and specific anti Lambda light chains polyclonal antiserum (2x10 mL) - Ratio: Dil.Sample/Reagent A/Reagent B: 1/23.3/5 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 40-1000 mg/dL.
(2x50; 2x10) 120 mL Turbidimetry
11110D Prealbumin 108 mL (2x50 + 2x4)
Immuno-turbidimetric determination of Prealbumin - The kit contains specific anti Prealbumin polyclonal antiserum (2x1 mL), antiserum diluent buffer (1x10 mL), reaction buffer (2x50 mL) in dedicated vials for automation - Ratio: Dil.Sample/Reagent A/Solution BC: 1/18/2 - Wavelength 340 nm - The Calibrator (REF 11200D; REF 11206D) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 9-180 mg/dL.
(2x50; 2x4) 108 mL Turbidimetry