Sentinel Diagnostics Laboratory

Sentinel Diagnostics Laboratory division comprehends the following product lines: Molecular Biology, Clinical Chemistry, Dedicated Reagents, FIT Systems (Fecal Immunochemical Test), Haemostasis, Immunology.

Each line includes a complete range of products aimed at satisfying the needs of medical analysis laboratories.

 

Latex Turbidimetry
Ref. Product Quantity Method Docs.
1150401 Lp(a)
Immuno-turbidimetric determination of Lp(a) in serum or plasma - The kit contains specific anti Lp(a) - Ratio: Sample/Reagent 1/Reagent 2: 1/62.5/15.7 - Wavelength 700 nm - The Calibrator (REF 11522D) and the Controls (REF 1152201) are available separately.
mL Turbidimetry
11505H Beta-2 Micro Latex CN 60 mL (2x20+2x10)
Immuno-turbidimetric determination of Beta-2-microglobulin in serum, plasma or urine - The kit contains specific anti BMG - Plasma-serum, Ratio: Sample/Reagent 1/Reagent 2: 2/180/80 - Urine, Ratio: Sample/Reagent 1/Reagent 2: 9/135/60 - Wavelength 570 nm - The Calibrator (REF 11524H) and the Controls (REF 11211A, 2 levels) are available separately - Measuring range: 0.2-80 mg/L (Serum) - Measuring range: 30- 8000 µg/L (Urine).
2x20; 2x10 mL Turbidimetry
11509A Ferritin Ultra CN 29 mL (1x19+1x10)
Immuno-turbidimetric determination of Ferritin in serum or plasma - The kit contains specific anti-Ferritin antibodies - Ratio Sample/Reagent 1/ Reagent 2: 1/20/10 - Wavelength 570 nm - Calibrator (REF 11525A) is available separately - Measuring range from 4 to 1000 ng/mL.
1x19; 1x10 mL Turbidimetry
11507H Myo Latex Autom CN 27 mL (1x20+1x7)
Immuno-turbidimetric determination of blood Myoglobin in serum or plasma - The kit contains specific anti human Myoglobin - Ratio: Sample/reagent 1/Reagent 2: 1/30/10 - Wavelength 570 nm - Calibrator (REF 11526D) available separately - Measuring range: 3-560ng/mL. Note: Barcode number, if printed on reagent labels, refers to the use of the product on Advia Series Analyzers.
1x20; 1x7 mL Turbidimetry
11510A Cystatin C 59 mL (1x46+1x13)
Immuno-turbidimetric determination of Cystatin C in serum or plasma - The kit contains specific anti human Cystatin C - Wavelength 540 nm - Ratio: Sample/Reagent 1/ Reagent 2: 1/75/17 - Calibrator (REF 11527S) and Controls (REF 11527C) are available separately - Measuring range from 0.05 to 8.00 mg/L.
1x46; 1x13 mL Turbidimetry
11504D Lp(a) Ultra 27 mL (1x18+1x9)
Immuno-turbidimetric determination of Lp(a) in serum or plasma - The kit contains specific anti Lp(a) - Ratio: Sample/Reagent 1/Reagent 2: 1/40/20 - Wavelength 700 nm - The Calibrator (REF 11522D) and the Controls (REF 1152201) are available separately - Measuring range: 3 -130 mg/dL. Note: Barcode number, if printed on reagent labels, refers to the use of the product on Advia Series Analyzers.
1x18; 1x9 mL Turbidimetry