Sentinel Diagnostics Laboratory

Sentinel Diagnostics Laboratory division comprehends the following product lines: Molecular Biology, Clinical Chemistry, Dedicated Reagents, FIT Systems (Fecal Immunochemical Test), Haemostasis, Immunology.

Each line includes a complete range of products aimed at satisfying the needs of medical analysis laboratories.

 

Accessories
Ref. Product Quantity Method Docs.
SD8020 Primary tubes and pediatric cups adapter 80 pcs
Adapters to be used with the FOB Gold® Tube NG (REF 11561N).
80 pcs
SD8003 Sample Tube Rack for SentiFob
1 pcs
SD8005 Reagent Rack for SentiFob
1 pcs
Calibrators
Ref. Product Quantity Method Docs.
11574 FOB Gold Calibrator Set H - 6 mL 6x(1x1)
6 concentration levels human hemoglobin calibrator - Liquid and ready to use -Open stability: 4 weeks at 2-8°C - Calibrator for all FOB Gold® kits.
6x(1x1) mL Turbidimetry
11573 FOB Gold Calibrator 4 mL (2x2)
Lyophilized calibrator of human hemoglobin, stable after reconstitution 8 hours at 2-8 °C or 60 days at -20 °C - To be used with FOB Gold®NG (REF 11560N).
2x2 mL Turbidimetry
Consumables
Ref. Product Quantity Method Docs.
SD8007 Cartuccia per Stampante C703
1 pcs
SD8000 Reaction Rotors (120 cuvettes x10 rotors)for SentiFob
10x120 pcs
SD6007 Sample cups tipo Hitachi 3 mL portacamp. conf. 6000 pz (BSA031)
Sample cups - 3 mL
6.000 pcs
SD8001 Concentrated Washing Solution 100 mL for SentiFob
100 mL
SD8002 Concentrated System Liquid 1L for SentiFob
1.000 mL
SD8006 Carta per Stampante for. A4 80gr fogli singoli 5x500
A4 printer paper
5x500 pcs
11561P FOB Gold Pack 500 pcs
500 plastic patient envelopes for the FOB Gold® collection tube - 500 Italian/English IFU to be given out to the patient.
500 pcs
Controls
Ref. Product Quantity Method Docs.
1157101 FOB Gold Low Level Control 2x1 mL
Low concentration human hemoglobin control – Liquid, ready to use – Open stability: 4 weeks at 2-8 °C – Control for all FOB Gold® kits calibrated with FOB Gold® Calibrator Set H (REF 11574).
2x1 mL mL Turbidimetry
11570 FOB Gold Control 8 mL 2x(2x2)
Lyophilized control set (2 levels) of human hemoglobin - Stable after reconstitution 8 hours at 2-8 °C or 60 days at -20 °C - To be used with FOB Gold® (REF 11560N) calibrated with the FOB Gold® Calibrator (REF 11573).
2x (2x2) mL Turbidimetry
11571 FOB Gold Control Set H - 4 mL 2x(1x2)
2 levels human hemoglobin controls - Liquid and ready to use - Open stability: 4 weeks at 2-8°C - Controls for all FOB Gold® calibrated with the FOB Gold® Calibrator Set H (REF 11574).
2x(1x2) mL Turbidimetry
Instruments
Ref. Product Quantity Method Docs.
580001 SentiFob Analyzer Unit
SentiFob® Analyzer Unit
1 pcs Other
580000 SentiFob System
Photometric analyzer for fully automatic Fecal Occult Blood determination - To be used together with FOB Gold® NG kit (REF 11560N) and the collection FOB Gold® Tube NG (REF 11561N) for feces sampling and as primary tubes on the analyzer - Throughput around 100 test/hr - System supplied with Computer, Monitor and Printer - Manual Bar Code reader available separately.
1 pcs Turbidimetry
580005 SentiFob Manual Bar Code Reader
1 pcs
580004 Printer for Analyzer Unit
Printer for Analyzer Unit
1 pcs
Reagents
Ref. Product Quantity Method Docs.
11561N FOB Gold Tube NG 100 tubes
Collection tube for feces sampling to be used as primary tube (13x98 mm - security seal) for automatic analyzers,calibrated with the FOB Gold® Calibrator (REF 11573).
100 pcs Turbidimetry
11560N FOB Gold NG 40 mL (1x20+1x20)
Latex turbidimetric quantitative determination of human hemoglobin in feces - Liquid reagents, ready to use.
1x20; 1x20 mL Turbidimetry
11561H FOB Gold Tube Screen 100 tubes
Collection Tube ( with tamper proof seal),containing a new buffer to reduce hemoglobin deterioration, for the collection of human feces samples. To be used as primary tube (13x98 mm) on automated Clinical Chemistry Analyzers calibrated with the FOB Gold® Calibrator Set H (REF 11574).
100 pcs Turbidimetry