Sentinel Diagnostics Laboratory division comprehends the following product lines: Molecular Biology, Clinical Chemistry, Dedicated Reagents, FIT Systems (Fecal Immunochemical Test), Haemostasis, Immunology.
Each line includes a complete range of products aimed at satisfying the needs of medical analysis laboratories.
ACE
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
1767001 | ACE Liquid Enzymatic method for the determination of angiotensin converting enzyme activity in serum or plasma - Wavelength 340 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/10 - Kinetic reading with reaction time 10 min - Linearity 120 U/L - The Calibrator (REF 1665001) and the Controls (REF 1667001, 2 levels) are available separately. |
2x20 mL | Colorimetric |
Acid Phosphatase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17617 | Acid Phosphatase (TOTAL AND PROSTATIC) - Kinetic colorimetric method - Wavelenght 405 nm - Stable 7 days at 2-8 °C from the preparation date - Temp. 37 °C - Citrate buffer - Substrate chromogen: alpha-naphtylphosphate-Fast Red TR salt - Ratio: Sample/Reagent: 1/10 - Kinetic reading - Lag phase 4 min - Reading time 2 min - Linearity 75 U/L. |
6x20 mL | Colorimetric |
Albumin
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
4726101 | Albumin BCP Bromocresol purple method |
Colorimetric | ||
17600H | Albumin Liquid Bromocresol green method - Wavelength 600 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent 1/120 - Immediate reading; color stable 1 hour - Linearity 7 g/dL. |
6x65 mL | Colorimetric |
Aldolase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17003 | Aldolase Enzymatic UV method with TPI-GDH - Wavelength 340 nm - THREE REAGENTS with min stability of 14 days from the preparation date - Ratio: Sample/Reagent 1/Reagent 2/Reagent 3: 1/12.5/0.25/0.05 - Kinetic reading with reaction time 25 min - Linearity 30 U/L - Sensitivity 1 U/L. |
5x20+2x1+1x0.5 mL | Colorimetric |
Alkaline Phosphatase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17308H | ALP Liquid DGKC optimized kinetic method - Wavelength 415 nm - Temperature 37 °C - DEA buffer and starter PNPP Liquid - Kinetic reading - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/50/12.5 - Lag phase 1 min - Reading time 3 min - Linearity 700 U/L. |
4x20; 1x20 mL | Colorimetric |
ALT/AST
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17224H | AST UV Liquid IFCC optimized UV method - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/10/1 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 200 U/L. |
2x65; 1x19 mL | Colorimetric | |
17234H | ALT UV Liquid IFCC optimized UV method - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent1/Reagent 2: 1/11/1.5 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 300 U/L. |
2x65; 1x19 mL | Colorimetric | |
17238A | ALT Color Microwell Enzymatic colorimetric test on microwell to be used for the determination of ALT with two reading points and calculation against calibrator - POX/POD/ESHPT method - Fixed-time Wavelength 550 nm - Ratio: Sample/Reagent A/Solution BC: 1/10/10 - Reaction time 30 min - Linearity 250 U/L - Lyophilized Calibrator (2x0.5 mL) included in the kit. |
Colorimetric |
Ammonia
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17660 | Ammonia Ultra Enzymatic UV method (GLDH) - SINGLE LIQUID REAGENT - Wavelength 340 nm - Ratio: Sample/Reagent: 1/11 - Linearity 1700 µg/dL - Standard included in the kit - Three levels Ammonia Controls (REF 16635) are available separately. |
3x20 mL | Colorimetric |
Amylase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17631H | Pancreatic Amylase Liquid Blocked pNPG7 (EPS) kinetic method according to IFCC recommendations - Inhibition of salivary amylase with double monoclonal antibodies- Wavelength 415 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/25/6.25 - the same R2 as in the alpha Amylase Liquid kit is used - Kinetic reading - Reaction time 8 min - Linearity 2000 U/L. |
1x65; 1x18 mL | Colorimetric | |
17632H | Amylase Liquid Protected pNPG7 (EPS) colorimetric method according to IFCC recommendations - Wavelength 415 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/25/6.25 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 1500 U/L. |
1x65; 1x18 mL | Colorimetric |
Bile Acids
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17002B | Bile Acids TBA Enzymatic colorimetric method with NBT - Wavelength 546 nm - Minimum stability of reagents 7 days after preparation - TWO REAGENTS (fixed time reaction in 5 min) - Ratio: Sample/Solution R1/Reagent 2: 1/2/0.5 - Linearity 200 µmol/L - Standard included (5x10 mL). Bile Acids Controls (REF 16002A) available separately. |
5x10; 1x13 mL | Colorimetric | |
1700201 | Total Bile Acids Liquid Enzymatic colorimetric method – Wavelength 404 nm – TWO LIQUID REAGENTS, ready to use – NEW GENERATION – Ratio Sample/Reagent 1/Reagent 2: 1/75/25 – Linearity 180 µmol/L – Calibrator included in the kit (1x1 mL) – Controls (REF 1600201) available separately. |
2x20; 2x9 mL | Colorimetric |
Bilirubin Direct
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17643H | Bilirubin Direct Liquid Colorimetric Jendrassik and Grof method - Wavelength 570 nm - Two analytical procedures: TWO REAGENTS with sample blank, n. tests (60-180) - Ratio: Sample/Reagent 1/Reagent 2: 1/15/0.5 and single reagent without sample blank n. tests (120-360) - Ratio: Sample/Reagent: 1/15 - Reaction time 2 min - Linearity 20 mg/dL. |
4x45; 1x15 mL | Colorimetric |
Bilirubin Total
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17642H | Bilirubin Total Liquid Colorimetric Jendrassik and Grof method - Wavelength 570 nm - Two analytical procedures: TWO REAGENTS with sample blank, n. tests (120-180) - Ratio: Sample/Reagent 1/Reagent 2: 1/15/0.5 and single reagent without sample blank, n. tests (240-360) Ratio: Sample/Reagent 1/15 - Reaction time 5 min - Linearity 20 mg/dL. |
7x45; 1x20 mL | Colorimetric |
Calcium
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17667H | Calcium Liquid Direct colorimetric method CPC (Cresolphtalein complexone) - Wavelength 600 nm - TWO REAGENTS LIQUID READY TO USE - Ratio: Sample/Reagent 1/Reagent 2: 1/25/10 - Reaction time 10 min at 37 °C - Linearity 20 mg/dL. |
3x55; 1x50 mL | Colorimetric |
Cholesterol
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17644H | Cholesterol Liquid Enzymatic colorimetric Trinder method - Wavelength 505 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 60 min - Linearity 700 mg/dL. |
6x65 mL | Colorimetric |
Cholesterol HDL
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17201H | Cholesterol HDL Liquid NG Direct method (“elimination technique”) in homogeneous phase - Without precipitation (US Patent N° 6,479,249 B2) - Wavelength 600 nm - TWO LIQUID REAGENTS - READY TO USE - Improved performances - Ratio: Sample/Reagent 1/Regent 2: 1/75/25 - Reaction time 8 min - Linearity 150 mg/dL - Calibrator (REF 1120201and REF 16550) and Controls (REF 1131001, REF 16150 and REF 16250) available separately. |
1x65; 1x20 mL | Colorimetric |
Cholesterol LDL
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17203H | Cholesterol LDL Liquid NG Direct method ("elimination technique") in homogeneous phase without precipitation (US Patent N° 6,194,164,B1) - Wavelength 600 nm - TWO LIQUID REAGENTS - READY TO USE - Improved performances - Ratio: Sample/Reagent 1/Reagent 2: 1/75/25 - Reaction time 10 min - Linearity 1000 mg/dL - Calibrator (REF 1120201 or REF 16550) and Controls (REF 1131001, REF 16150 and REF 16250) available separately. |
1x65; 1x20 mL | Colorimetric |
Cholinesterase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17019H | Cholinesterase Liquid Kinetic-colorimetric optimized method according to DGKC recommendations - Substrate Butyryltiocholine - TWO LIQUID REAGENTS - Wavelength 415 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/50/10 - Kinetic reading - Lag phase 90 sec - Reading time 90 sec - Linearity 22.000 U/L.- FDA 510 (K) number: K981800. |
2x50; 1x20 mL | Colorimetric |
CK
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17296H | CK-NAC Liquid Kinetic method according to IFCC recommendations - Wavelength 340 nm - Temperature 37 °C - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/20/5 at 37 °C - Kinetic reading - Lag phase 2 min - Reading time 3 min - Linearity 1000 U/L. |
1x65; 1x18 mL | Colorimetric |
CK-MB
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17649H | CK-MB Liquid Immunological test method for the determination of CK-MB sub-units by inhibitor antibodies - Wavelength 340 nm - Tempeature 37 °C – TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/20.8/4.2 - Measuring range up to 1000 U/L – Calibrator (REF 16299C) and Control (REF 16299S) available separately. |
1x65; 1x15 mL | Colorimetric |
Copper
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17638H | Copper Direct colorimetric DiBr-PAESA method - Wavelength 570 nm - Without deproteinization on serum and plasma - TWO REAGENTS stable 45 days at 2-8 °C after preparation - End-Point reaction in 5 min at 37 °C - color stable 60 min - Ratio: Sample/Reagent 1/Reagent 2: 1/20/4 - Linearity 500 µg/dL - Standard included in the kit. |
5x20; 1x21 mL | Colorimetric | |
17106 | Copper |
5x10; 1x3 mL | Colorimetric | |
17109 | Copper Urine Direct colorimetric method DiBr-PAESA - Wavelength 582 nm - Without deproteinization on urine - Ratio: Sample/Reagent 1/Reagent 2: 10/1/1 - End-Point reaction in 5 min at room temperature - Linearity 20 µg/dL - Standard included in the kit. |
4x3 mL | Colorimetric |
Creatinine
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17654H | Creatinine Enz Liquid Enzymatic colorimetric Trinder method (SOX-POD-ESPMT) without deproteinization with starter reagent - Wavelength 546 nm - Fixed time reaction: reaction time 5 min after starter with blank sample subtraction - Ratio: Sample/Reagent 1/Reagent 2: 1/45/15 - Linearity 50 mg/dL. |
2x50; 2x18 mL | Colorimetric | |
17609H | Creatinine Liquid Kinetic method with alkaline picrate (Jaffe' mod.) - Wavelength 505 nm - Without deproteinization - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/6.25/6.25 - Fixed time reaction - Lag phase 60 sec - Reading time 1 min - Linearity 15 mg/dL. |
3x65; 3x65 mL | Colorimetric |
Dibucaine
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17018 | Dibucaine CHE Liquid Auxiliary reagent for the determination of the dibucaine number (DN); to be used with Cholinesterase Liquid REF 17019H - Stable 30 days at 2-8 °C - Reaction time 3 min. |
6x50 mL | Colorimetric |
Fructosamine
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17350H | Fructosamine Colorimetric method with NBT - SINGLE REAGENT stable 14 days after reconstitution - Ratio: Sample/Reagent: 1/19.2 - Wavelength 546 nm - Fixed Time reaction from 9 to 10 min - Calibrator is included in the kit, Controls (REF 16352 and REF 16353) available separately. |
3x18 mL | Colorimetric | |
1735001 | Fructosamine Liquid Colorimetric method with NBT – TWO LIQUID REAGENTS, ready to use – NEW GENERATION – Ratio Sample/Reagent 1/Reagent 2 : 1/75/25 – Wavelength 548 nm – The calibrators (REF 1635101) and the controls (REF 1635201) are available separately. |
3x14; 3x6 mL mL | Colorimetric |
Gamma - GT
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17336H | Gamma GT Liquid Kinetic colorimetric according to Szaz mod/IFCC mod. method. - Buffer and substrate liquid Carboxy-Glupa - Wavelength 415 nm - Temperature 37 °C - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/10/2.5 - Kinetic reading - Lag phase 30-60 sec - Reading time 3 min - Linearity 700 U/L. |
1x65; 1x18 mL | Colorimetric |
Glucose
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17630H | Glucose Liquid Enzymatic colorimetric Trinder method - Wavelength 505 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 10 min - Color stable 60 min - Linearity 400 mg/dL. |
6x65 mL | Colorimetric |
Glucose-6-phosphate dehydrogenase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17005 | G6P-DH Enzymatic UV method with NADP on erythrocytes - Wavelength 340 nm - THREE REAGENTS, stable at least 4 weeks after preparation - Kinetic reading - Lag phase 0 sec - Reading 3 min - Total reaction time 8 min (erythrocytes) - Controls (REF 1600501) available separately. |
100 mL | Colorimetric |
HBDH
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17636 | HBDH Liquid a-hydroxybutirate deydrogenase DGKC optimized UV method - TWO LIQUID REAGENTS - Wavelength 340 nm - Temp. 30-37 °C - Ratio: Sample/Reagent 1/Reagent 2: 1/30/3 - Kinetic reading - Lag phase 60 sec - Reading time 3 min - Linearity 500 U/L at 37 °C. |
2x50; 1x12 mL | Colorimetric |
Hemoglobin A1c
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
1741501 | HbA1c Direct Latex Hemoglobin Direct immuno-turbidimetric latex determination - Wavelength 600 nm - TWO LIQUID REAGENTS - 50 days stability after Reagent opening - Ratio: Sample/Reagent 1/Reagent 2: 1/37.5/12.5 - Linearity: 1.0%-16% HbA1c - Calibrator (REF 1741801), Control (REF 1741901) and Diluent* for hemolysate preparation (REF 1741601) available separately. * Hemolysis Reagent HbA1c (2 x70 mL) |
1x30; 1x10 mL | Colorimetric | |
1741601 | Hemolysis Reagent HbA1c Auxiliary reagent to be used with the kit HbA1c Direct Latex (REF 1741501) for samples hemolysis. |
2x70 mL mL | Colorimetric |
Homocysteine
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17370H | Homocysteine Liquid Enzymatic Homocysteine assay in serum and heparinised plasma using a new Liquid Stable (LS) 2-part homocysteine reagent for quantitative determination - The concentration of HCY in the sample is directly proportional to the conversion rate of NADH at 340 nm – TWO REAGENTS – Ratio: Sample/Reagent 1/Reagent 2: 1/15.1/1.5 – Linearity 1-46 µmol/L – Sensitivity 1 µmol/L - Calibrator included in the kit – Controls (REF 16370S) available separately. |
1x30; 1x5 mL | Colorimetric |
Iron
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17648H | Iron Liquid Direct colorimetric Ferene method without deproteinization on serum and plasma - Ratio: Sample/Reagent 1/Reagent 2: 1/12.5/1 - TWO LIQUID REAGENTS - Wavelength 600 - Linearity 1000 µg/dL - End-Point reaction in 5 min at 37 °C - Sample blank required - Volumes R1 and R2 are balanced for automated analyzers. |
3x65; 1x15 mL | Colorimetric |
Iron Binding Capacity
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
1763901 | UIBC Liquid NG Unsaturated Iron Binding Capacity – Determination with Ferene method – TWO LIQUID REAGENTS, ready to use – NEW GENERATION – Ratio Sample/Reagent 1/Reagent 2 : 1/7/2 – Wavelength 604 nm - Linearity 500 µg/dL – Standard included in the kit (1x2 mL) – Controls (REF 16150 and REF 16250) are available separately. |
1x25; 2x9 mL mL | Colorimetric | |
17639 | UIBC Liquid Unsaturated Iron Binding Capacity - Determination with direct Ferene method in homogeneous phase with liquid reagents - Wavelength 593 nm - TWO REAGENTS - Reagents stable 60 days at 2-8 °C - Ratio: Sample/Reagent 1/Reagent 2: 1/10/1 - Standard included in the kit - Reaction time 10 min. |
2x40; 1x11 mL | Colorimetric |
Lactate
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17285 | Lactate Dry-Fast Enzymatic colorimetric Trinder method - Plasma or liquor - Without sample blank - Wavelength 540 nm - SINGLE REAGENT stable 30 days at 2-8 °C after reconstitution - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 60 min - Linearity 210 mg/dL. |
5x10 mL | Colorimetric | |
1728601 | Lactate Liquid Enzymatic colorimetric determination of Lactate on plasma - TWO LIQUID REAGENTS ready to use - Ratio: Sample/Reagent 1/Reagent 2: 1/83.3/16.7 - Linearity 15 mmol/L (135 mg/dL). |
2x25 + 2x5 mL | Colorimetric |
LDH
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17294H | LDH Liquid Optimized SFBC UV method (pyruvate-lactate) - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/50/5 - Kinetic reading - Lag phase 60 sec - Reading time 3 min - Linearity 1200 U/L - Volumes R1 and R2 are balanced for automated analyzer. Note - Recommended calibrator: REF 16550 Clin Chem Cal (Mod. DGKC). |
3x65; 1x20 mL | Colorimetric |
Lipase
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17616H | Lipase Color Liquid Colorimetric direct method with long chain substrate (dilauryl-glyceroglutaric-methylresorufineester) specific for lipase - Liquid emulsion - TWO LIQUID REAGENTS - Temperature 37 °C - Wavelength 570 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/100/20 - Kinetic reading - Lag phase 1 min - Reading 2 min - Linearity 250 U/L (methylresorufine units) - FDA 510 (K) number: K961179. |
4x50; 2x21 mL | Colorimetric | |
17401B | Lipase Color Liquid Colorimetric direct method with long chain substrate (dilauryl-glyceroglutaric-methylresorufineester) specific for lipase - Liquid emulsion - TWO LIQUID REAGENTS - Temperature 37 °C - Wavelength 580 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/100/20 - Kinetic reading - Lag phase 1 min - Reading 2 min - Linearity 250 U/L (methylresorufine units) - Calibrator included in the kit - FDA 510 (K) number: K961179. |
4x10; 1x8 mL | Colorimetric | |
1761601 | Lipase NG Colorimetric direct method with long chain substrate (dilauryl-glyceroglutaric-methylresorufine ester) specific for lipase – Liquid emulsion – NEW GENERATION – WO LIQUID REAGENTS – Temperature: 37 °C – Wavelength 570 nm – Ratio Sample /Reagent 1/Reagent 2: 1/100/35 – Linearity 300 U/L (methylresorufine units) – Traceability vs. Roche Diagnostics Method. |
1x55;1x20 mL | Colorimetric |
Magnesium
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17637H | Magnesium Liquid Direct colorimetric method Xilidil Blue-1 - Wavelength 505 nm - LIQUID SINGLE REAGENT - Without sample blank - Ratio: Sample/Reagent: 1/100 - Immediate reading - Color stable 30 min - Linearity 10 mg/dL. |
6x20 mL | Colorimetric |
Phospholipids
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17320 | Phospholipids Enzymatic colorimetric Trinder method - Wavelength 520 nm - SINGLE REAGENT stable 30 days at 2-8 °C after reconstitution - Ratio: Sample/Reagent: 1/100 - End-Point reaction in 10 min - Color stable 30 min - Linearity 900 mg/dL. |
5x10 mL | Colorimetric |
Phosphorus
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17619H | Phosphorus Molybdenum blue direct method - Wavelength 650 nm - SINGLE REAGENT stable 60 days at 2-8 °C after reconstitutions - Ratio: Sample/Reagent: 1/30 - End-Point reaction 3 min - Color stable 60 min - Linearity 10 mg/dL. |
6x65 mL | Colorimetric |
Proteins
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17620H | Total Proteins Direct colorimetric Biuret method - Wavelength 546 nm - LIQUID SINGLE REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 15 min - Color stable 60 min - Linearity 10 g/dL. |
6x65 mL | Colorimetric | |
1727501 | Urine Proteins Direct colorimetric method with Pyrogallol Red at high linearity - Wavelength 600 nm - Without sample blank - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent 1/100 - End-point reaction 1 min - Color stable 30 min - Linearity 210 mg/dL - Sensitivity 1 mg/dL - Standard included in the kit. Recommended controls: (REF 143131 Human Urine Chemistry Ctrl 1 e REF 143231 Human Urine Chemistry Ctrl 2) - Quantimetrix Corporation - CA, USA. |
4x20 mL | Colorimetric |
Triglycerides
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17624H | Triglycerides Liquid Enzymatic colorimetric Trinder method (TOOS) - Wavelength 546 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 30 min - Linearity 1000 mg/dL. |
6x65 mL | Colorimetric |
Urea
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17629H | Urea Liquid Kinetic UV method Urease-GLDH - Wavelength 340 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/100/10 - Fixed time reading - Lag phase 30 sec - Reading 30 sec - Linearity 350 mg/dL - Volumes R1 and R2 are balanced for automated analyzer. |
3x65; 1x20 mL | Colorimetric |
Uric Acid
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17658H | Uric Acid Liquid Enzymatic Trinder method (TOOS) on serum, plasma and urine - Wavelength 546 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/42 - End-Point reaction 5 min - Color stable 10 min - Linearity 25 mg/dL. |
4x65 mL | Colorimetric |
Zinc
Ref. | Product | Quantity | Method | Docs. |
---|---|---|---|---|
17640H | Zinc Direct colorimetric method with 5-Br-PAPS - Wavelength 570 nm - Without deproteinization on serum, plasma and seminal fluid - TWO REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/20/2 - End-Point reaction 30 sec. at 37 °C - Color stable 60 min. - Linearity 2000 µg/dL - Standard included in the kit. |
5x20; 1x11 mL | Colorimetric | |
17255 | Zinc |
5x10; 1x5 mL | Colorimetric |