<?xml version="1.0"?>
<rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:sy="http://purl.org/rss/1.0/modules/syndication/" xmlns:admin="http://webns.net/mvcb/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:content="http://purl.org/rss/1.0/modules/content/">
   <channel>
      <title>Scientific Area Sentinel Diagnostics</title>
      <link>http://www.sentineldiagnostic.com</link>
      <description>Scientific Area Sentinel Diagnostics</description>
      <copyright>Copyright (C) Sentinel Diagnostics</copyright>
      <ttl>5</ttl>
      <item>
         <title>Evaluation of NGAL Test ™, a fully-automated neutrophil
gelatinase-associated lipocalin NGAL immunoassay
on Beckman Coulter AU 5822</title>
         <description>&lt;FONT size=2 face=Times-Bold&gt;&lt;FONT size=2 face=Times-Bold&gt;
&lt;P align=left&gt;Giuseppe Lippi&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=1 face=Times-Bold&gt;&lt;FONT size=1 face=Times-Bold&gt;,&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=2 face=Times-Bold&gt;&lt;FONT size=2 face=Times-Bold&gt; Rosalia Aloe&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=2 face=Times-Bold&gt;&lt;FONT size=2 face=Times-Bold&gt;, Antonietta Storelli&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=2 face=Times-Bold&gt;&lt;FONT size=2 face=Times-Bold&gt;, Gianfranco Cervellin e&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=2 face=Times-Bold&gt;&lt;FONT size=2 face=Times-Bold&gt; Tommaso Trenti &lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=1 face=Times-Bold&gt;&lt;FONT size=1 face=Times-Bold&gt;&lt;/P&gt;&lt;/FONT&gt;&lt;/FONT&gt;
&lt;a href="/upload_doc/news/92-1-cclm 2011 8391.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-ngal-test-%e2%84%a2-a-fully-automated-neutrophilgelatinase-associated-lipocalin-ngal-immunoassayon-beckman-coulter-au-5822.aspx</link>
         <pubDate>08/05/2012 11.34.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Valutazione di un nuovo metodo per la determinazione del sangue occulto nelle feci FOB GOLD NG su COBAS C6000
SIBioC 2011, Parma</title>
         <description>M.Tagliazucchi, A.Fortuna, C.Calasso, M.C.Casolari
&lt;a href="/upload_doc/news/91-1-Poster 140_Abstract_FOB.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/valutazione-di-un-nuovo-metodo-per-la-determinazione-del-sangue-occulto-nelle-feci-fob-gold-ng-su-cobas-c6000sibioc-2011-parma.aspx</link>
         <pubDate>05/12/2011 16.03.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Preliminary evaluation of a new immunoturbidimetric kit for the measurement of NGAL
SIBioC 2011, Parma</title>
         <description>C.Villa, G.Scarsi
&lt;a href="/upload_doc/news/89-1-145_Abstract_GA.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/preliminary-evaluation-of-a-new-immunoturbidimetric-kit-for-the-measurement-of-ngalsibioc-2011-parma.aspx</link>
         <pubDate>05/12/2011 16.00.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Determinazione dell'sd LDL colesterolo "diretto" su AU 600 Beckman
SIBioC 2011, Parma</title>
         <description>&lt;P&gt;G.Cangiano, A.Latte, E. Di Maina, G.Buccino, C.Taranto, M.M. D&lt;SPAN style="LINE-HEIGHT: 115% FONT-FAMILY: Times New Roman,serif FONT-SIZE: 11pt mso-fareast-font-family: Calibri mso-fareast-theme-font: minor-latin mso-ansi-language: IT mso-fareast-language: EN-US mso-bidi-language: AR-SA"&gt;'Ambrosio, A.Di Maio, M.D&lt;SPAN style="LINE-HEIGHT: 115% FONT-FAMILY: Times New Roman,serif FONT-SIZE: 11pt mso-fareast-font-family: Calibri mso-fareast-theme-font: minor-latin mso-ansi-language: IT mso-fareast-language: EN-US mso-bidi-language: AR-SA"&gt;'Amora, A.Sarappa&lt;/SPAN&gt;&lt;/SPAN&gt;&lt;/P&gt;
&lt;a href="/upload_doc/news/88-1-114 - 2011 SIBIOC sd LDL_NA.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/determinazione-dellsd-ldl-colesterolo-diretto-su-au-600-beckmansibioc-2011-parma.aspx</link>
         <pubDate>05/12/2011 15.59.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Le statine riducono il livello delle SD-LDL nei pazienti sottoposti a dialisi peritoneale
SIBioC 2011, Parma  </title>
         <description>A.Bevilacqua, A.Clementi, F.Fabbi, B.Faresin, F.Zerbato, U.Pizzolato, L.Scarparo, E.Scalzotto, D.Giavarina, C.Ronco, G.Soffiati
&lt;a href="/upload_doc/news/87-1-45-sLDL-Statins_VI.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/le-statine-riducono-il-livello-delle-sd-ldl-nei-pazienti-sottoposti-a-dialisi-peritonealesibioc-2011-parma.aspx</link>
         <pubDate>05/12/2011 15.55.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>A Rapid and Innovative Method for the Identification of the Commonest G6PD Italian Mutations
SIBioC 2011, Parma</title>
         <description>A. Minucci, L.Gentile, S. Rocchetti, C.Zuppi, B.Giardina, E. Capoluongo
&lt;a href="/upload_doc/news/85-1-G6PDrapid1.ppt" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/a-rapid-and-innovative-method-for-the-identification-of-the-commonest-g6pd-italian-mutationssibioc-2011-parma.aspx</link>
         <pubDate>24/11/2011 17.49.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>A New Laboratory Friendly Platform to Detect the Celiac Disease associated HLA-DQ2 and DQ8 Haplotype
SIBioC 2011 - Parma</title>
         <description>D.Bozzato, F.Navaglia, E.Rossi, M.Gramegna, M.Pelloso, R.favero, E.Greco, A.Padoan, S.Moz, P.Fogar, C-F.Zambon, D.Basso, M. Plebani
&lt;a href="/upload_doc/news/83-1-poster_sentinel_celiachia SIBIOC 2011.ppt" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/a-new-laboratory-friendly-platform-to-detect-the-celiac-disease-associated-hla-dq2-and-dq8-haplotypesibioc-2011-parma.aspx</link>
         <pubDate>16/11/2011 14.05.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>A New and Easy Way to Molecular Testing
SIMeL 2010, Verona</title>
         <description>M. Gramegna, A. Moiana
&lt;a href="/upload_doc/news/67-1-posterSIMEL 2010.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/a-new-and-easy-way-to-molecular-testingsimel-2010-verona.aspx</link>
         <pubDate>16/11/2011 12.23.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>PCR-based Kit for the Screening and Typing of Malaria Infections
EARCR 2009, Triuggio MI</title>
         <description>M.Gramegna, A. Moiana, L. Coltella, C.Russo, S.Gatti
&lt;a href="/upload_doc/news/81-1-SENTINEL-PCR_BASED-EARCR 2009.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/pcr-based-kit-for-the-screening-and-typing-of-malaria-infectionsearcr-2009-triuggio-mi.aspx</link>
         <pubDate>16/11/2011 12.19.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>A New Universal and Self - Containing Lyophlized PCR Mix
SIBIOC 2010, Roma</title>
         <description>M. Gramegna, E. Castiglioni, A. Moiana, M. Zanussi, M. Ferrari
&lt;a href="/upload_doc/news/68-1-posterSibioc 2010 1.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/a-new-universal-and-self-containing-lyophlized-pcr-mixsibioc-2010-roma.aspx</link>
         <pubDate>16/11/2011 12.15.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Sviluppo di un test PCR per la diagnosi delle infezioni da Toxoplasma Gondii
AMCLI 2009, Rimini</title>
         <description>A. Moiana, M. Gramegna, F. Genco, V. Meroni
&lt;a href="/upload_doc/news/64-1-poster Toxo AMCLI 2009-4.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/sviluppo-di-un-test-pcr-per-la-diagnosi-delle-infezioni-da-toxoplasma-gondiiamcli-2009-rimini.aspx</link>
         <pubDate>16/11/2011 12.11.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Validation of a New Freeze-Dried PCR Universal Master Mix
AACC 2010, Anaheim - California</title>
         <description>M. Gramegna, E. Castiglioni, A. Moiana, M. Zanussi, M. Ferrari&lt;BR&gt;La Sentinel ha di recente sviluppato una piattaforma universale originale e proprietaria per la PCR utilizzando miscele di amplificazione universali, che permette di conservarle a temperatura ambiente, senza necessità di frigoriferi e congelatori. Scopo dello studio è di valutare le performance di diverse miscele liofilizzate per applicazioni di biologia molecolare, sia per uso di ricerca che di diagnostica di laboratorio.
&lt;a href="/upload_doc/news/57-1-STAT_NAT_AACC_2010.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/validation-of-a-new-freeze-dried-pcr-universal-master-mixaacc-2010-anaheim-california.aspx</link>
         <pubDate>16/11/2011 12.10.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Innovative Real Time PCR Assay for the Screening and the Drug Reesistance Detection of Mycobacteria
SIBioC 2011, Parma</title>
         <description>A.Moiana, M.L.Incandela, S.Buroni, M.R.Pasca, M. Gramegna, G.Riccardi
&lt;a href="/upload_doc/news/79-1-poster SIBIOC 2011 def.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/innovative-real-time-pcr-assay-for-the-screening-and-the-drug-reesistance-detection-of-mycobacteriasibioc-2011-parma.aspx</link>
         <pubDate>16/11/2011 12.06.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Valutazione di un nuovo test diagnostico basato sulla PCR per lo screening e la tipizzazione di infezioni malariche
SIBioC 2009, Napoli
</title>
         <description>&lt;P&gt;M. Gramegna, A. Moiana, L. Coltella, C. Russo, S. Gatti&lt;/P&gt;
&lt;a href="/upload_doc/news/63-1-poster sibioc 2009 AM.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/valutazione-di-un-nuovo-test-diagnostico-basato-sulla-pcr-per-lo-screening-e-la-tipizzazione-di-infezioni-malarichesibioc-2009-napoli.aspx</link>
         <pubDate>16/11/2011 12.02.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Not Invasive Doagnosis of Leishmania Infection by a novel PCR-based Assay  
AACC 2009, Phoenix -  Arizona</title>
         <description>M. Gramegna, A. Moiana, S. Gatti, L. Coltella, C. Russo
&lt;a href="/upload_doc/news/72-1-3-LEISHMANIA-AACC 2009.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/not-invasive-doagnosis-of-leishmania-infection-by-a-novel-pcr-based-assay-aacc-2009-phoenix-arizona.aspx</link>
         <pubDate>16/11/2011 11.55.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Diagnosi dell'infezione malarica: Confronto tra metodi tradizionali e un nuovo test in PCR Multiplex in formato liofilo
AMCLI 2011, Rimini</title>
         <description>A.Moiana, M.Gramegna, F.A.Solari, S.Gatti 
&lt;a href="/upload_doc/news/76-1-poster Malaria AMCLI 2011 def.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/diagnosi-dellinfezione-malarica-confronto-tra-metodi-tradizionali-e-un-nuovo-test-in-pcr-multiplex-in-formato-liofiloamcli-2011-rimini.aspx</link>
         <pubDate>16/11/2011 11.50.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of a new Syphilis assay on Vitros 5600 Integrated System</title>
         <description>G. Longo, C. Bitella, M. La Motta, R. Lucini, F. Rota, A. Godani Serra, E. Vigo
&lt;a href="/upload_doc/news/73-1-2010__vol25_n4_02.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-a-new-syphilis-assay-on-vitros-5600-integrated-system.aspx</link>
         <pubDate>23/06/2011 17.15.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of Sentinel Cholinesterase Liquid Assay on LX20 and DXC600 Systems</title>
         <description>F. Rota, E. Marelli, A. Cugini, F. Vespasiani, M. Valdambrini&lt;BR&gt;Valutazione del kit Sentinel della “Cholinesterase Liquid” sugli analizzatori per Chimica Clinica Beckman Coulter Synchron® LX20 ed UniCel® DXC 600. Scopo dello studio è quello di valutare le performances analitiche del kit e di introdurre sul mercato un’ applicazione validata col marchio CE.
&lt;a href="/upload_doc/news/55-1-CHE_AACC_2010.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-sentinel-cholinesterase-liquid-assay-on-lx20-and-dxc600-systems.aspx</link>
         <pubDate>05/05/2011 11.17.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of Sentinel CK-MB UDR Assay on LX20 and DXC600 Systems</title>
         <description>F. Rota, E. Marelli, A. Cugini, F. Vespasiani, L. De Angelis&lt;BR&gt;Valutazione del kit Sentinel “CK-MB UDR” sugli analizzatori per Chimica Clinica Beckman Coulter Synchron® LX20 ed UniCel® DXC 600. Scopo dello studio è quello di valutare le performance analitiche del kit e di verificarne le specifiche analitiche sulla base della variabilità biologica dell’ analita secondo la Ricos. Il test inoltre è un bi-reagente liquido pronto all’ uso e non richiede alcuna procedura dicalibrazione.
&lt;a href="/upload_doc/news/56-1-CKMB_AACC_2010.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-sentinel-ck-mb-udr-assay-on-lx20-and-dxc600-systems.aspx</link>
         <pubDate>15/04/2011 12.53.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of Sentinel ACP-NP Assay on AU400 and AU2700 Systems</title>
         <description>A. Cugini, L. De Angelis, F. Vespasiani, M. Valdambrini, E. Bianchi, G. Fumagalli&lt;BR&gt;Valutazione dei kit Sentinel  per la Fosfatasi Acida Totale ACP e della Fosfatasi Acida Non Prostatica ACP-NP sugli analizzatori automatici  Beckman Coulter  AU400 ed AU2700 per verificarne le prestazioni analitiche anche sulla base della variabilità biologica dell’ analita secondo la Ricos.
&lt;a href="/upload_doc/news/61-1-ACP_2010.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-sentinel-acp-np-assay-on-au400-and-au2700-systems.aspx</link>
         <pubDate>15/04/2011 12.46.00</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>New Syphilis Assay on Vitros 5600 Clinical Chemistry System</title>
         <description>R. Lucini, F. Rota, C. Bitella, A. Godani Serra, E. Vigo&lt;BR&gt;Valutazione sull´analizzatore per Chimica Clinica Vitros 5600 di un nuovo test immunometrico in fase omogenea per il "Treponema pallidum". Lo studio analizza le performance del test e la sua accuratezza comparandole col test di emoagglutinazione (TPHA).
&lt;a href="/upload_doc/news/53-1-Syphilis.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/new-syphilis-assay-on-vitros-5600-clinical-chemistry-system.aspx</link>
         <pubDate>22/10/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Programa Piloto de Preveciòn de Càncer de Colòn y Recto</title>
         <description>J. Cruzado Quevedo, F. Pérez Riquelme, E. Torrella Cortès, M. C. Cavas Martìnez, P. Esteban Garcìa, J. J. Gutiérrez Garcìa, e Grupo Investigaciòn PCaColon y Recto &lt;BR&gt;Esperienza e primi risultati del programma pilota di prevenzione del tumore al colon-retto nella regione di Salud VI della Murcia&amp;nbsp;Spagnola. La Regione di Salud VI integra 13 Zonas de Salud ed un Ospedale Regionale per un totale di 35.771 persone.
&lt;a href="/upload_doc/news/COLON_MADRID_7.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/programa-piloto-de-prevecion-de-cancer-de-colon-y-recto.aspx</link>
         <pubDate>10/03/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Small Dense LDL-cholesterol: a superior diagnostic marker</title>
         <description>&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;&lt;B&gt;Yasuki Ito, Yosuke Meguro, Kunio Kamata, Tsutomu Hirano, Makoto Kinoshita, Mariko Shiba, Tetstuo Shoji, Shinji Koba, Akira Tanaka, Gen Yoshino&lt;BR&gt;&lt;/B&gt;&lt;/FONT&gt;&lt;FONT face=verdana color=#666666&gt;Studio sulle componenti piccole e dense del colesterolo LDL come marker diagnostico d'eccellenza per l'iperlipidemia combinata familiare (FCHL): le frazioni sd LDL vengono determinate utilizzando il kit s LDL-C'SEIKEN' col metodo della precipitazione con eparina-magnesio e misurando il diametro medio dell' LDL attraverso la metodica del gradiente 2-16% in gel elettroforesi. Sensibilità e specificità sono state comparate utilizzando 4 differenti parametri per discriminare la vera FCHL da altri tipi di ipercolesterolemie familiari.&lt;/FONT&gt;&lt;/FONT&gt;
&lt;a href="/upload_doc/news/EAS08_POSTER.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/small-dense-ldl-cholesterol-a-superior-diagnostic-marker.aspx</link>
         <pubDate>24/02/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>FOBT Common Guaiac vs. Immunochemical Test</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;H. J. Roth, H. Schmidt-Gayk&lt;/b&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Sono stati studiati e comparati i test di ricerca del sangue occulto nelle feci&amp;nbsp;(FOB) col popolare metodo del guaiaco e con i più recenti test immunochimici (iFOBTs). La maggiore sensibilità di questi ultimi favorisce gli screening di massa per la prevenzione del cancro del colon-retto (CRC), grazie alla miglior definizione del cut-off e bilanciando meglio sensibilità e specificità.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/ISOBM.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/fobt-common-guaiac-vs-immunochemical-test.aspx</link>
         <pubDate>23/02/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Comparison of CT colonography, colonoscopy, sigmoidoscopy and FOBT for adenoma detection</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;A. Graser, P. Stieber, D. Nagel, C. Shafer, D. Horst, C. R. Becker, K. Nikolaou, A. Lottes, S. Geisbusch, H. Kramer, A. C. Wagner, H. Diepolder, J. Schirra, H. J. Roth, D. Seidel, B. Goke, M. F. Reiser, F. T. Kolligs&lt;/B&gt;&lt;/FONT&gt;&lt;FONT face=verdana color=#666666 size=1&gt;&lt;BR&gt;Comparazione delle caratteristiche di 5 differenti test di screening per la diagnosi della neoplasia del colon: colonografia (CTC), colonoscopia (OC), sigmoscopia (FS), sangue occulto immunometrico (FIT), sangue occulto&amp;nbsp;rapido (FOBT).&lt;/FONT&gt;&lt;BR&gt;
&lt;a href="/upload_doc/news/colontumors.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/comparison-of-ct-colonography-colonoscopy-sigmoidoscopy-and-fobt-for-adenoma-detection.aspx</link>
         <pubDate>11/02/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Colorectal cancer screening by quantitation of haemoglobin in card</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;C. M. Matthew, K. McKay, R. J. C. Steele, C. G. Fraser&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Lo screening del tumore del colon-retto è in continuo aumento in tutto il mondo: uno dei test più diffusi è la ricerca del sangue occulto nelle feci mediante il test del guaiaco (gFOBT) su card, mentre si stanno affermando sempre più test immunochimici più specifici (FIT) che richiedono la raccolta delle feci in un comodo tubo adatto agli analizzatori automatici.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/FraserGE.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/colorectal-cancer-screening-by-quantitation-of-haemoglobin-in-card.aspx</link>
         <pubDate>09/01/2009</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Assessment of an Affinity Based Point of Care System for HbA1c</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;A. Mosca, R. Paleari, G. Passerini, F Ceriotti&lt;/b&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Valutazione della performance analitica del nuovo Point of Care system (POCT) Afinion™ AS100 Analyzer (Axis-Shield, Oslo, N) per l'emoglobina glicata (HbA1c) basato sulla cromatografia di affinità al boronato. Il metodo fornisce il risultato in soli 3 minuti, utilizza&amp;nbsp;1,5 &amp;#956;L di sangue intero, non risente della presenza di HbS e HbC ed i risultati sono forniti in accordo con la standardizzazione NGSP.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/ADAAMfinale.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/assessment-of-an-affinity-based-point-of-care-system-for-hba1c.aspx</link>
         <pubDate>16/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of SENTINEL CH. special assays on the ABBOTT c16000 Clinical Chemistry System</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;R. Lucini, R. Dioli, E. Marelli, F. Rota, M. Fritz, H. Troonen&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Ottimizzazione di alcuni test SENTINEL CH. su un nuovo modello di analizzatore ad alta produttività analitica: l' ABBOTT ARCHITECT c16000.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/assaysonc16000.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-sentinel-ch-special-assays-on-the-abbott-c16000-clinical-chemistry-system.aspx</link>
         <pubDate>09/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Preliminary Evaluation of a new Cystatin C Assay on the ABBOTT Clinical Chemistry Systems</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;R. Lucini, R. Dioli, L. De Angelis, F. Rota, M. Fritz, H. Troonen&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Valutazione di un nuovo metodo per la Cistatina C sugli&amp;nbsp;analizzatori per chimica clinica della Abbott e verifica delle performance analitiche secondo le linee guida della NACB.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/CystatinC.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/preliminary-evaluation-of-a-new-cystatin-c-assay-on-the-abbott-clinical-chemistry-systems.aspx</link>
         <pubDate>09/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of MULTIGENT Lithium assay on the ABBOTT Clinical Chemistry Systems</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;F. Rota, L. De Angelis, R. Vannest, B. Nance&lt;/B&gt;&lt;BR&gt;Validazione&amp;nbsp;del test per il Litio MULTIGENT sugli analizzatori ABBOTT ARCHITECT c8000 ed AEROSET. Valutazione delle performance analitiche rispetto alle raccomandazioni HKFA/CLIA sull'Errore Totale.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/LithiumAACC.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-multigent-lithium-assay-on-the-abbott-clinical-chemistry-systems.aspx</link>
         <pubDate>08/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of MULTIGENT Creatinine (Enzymatic) Liquid on the ABBOTT Clinical Chemistry Systems</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;F. Rota, F.Magro, B. Nance, H. V. Markle&lt;/B&gt;&lt;BR&gt;Validazione&amp;nbsp;del test della&amp;nbsp;Creatinina Enzimatica Liquida&amp;nbsp;MULTIGENT sugli analizzatori ABBOTT&amp;nbsp;ARCHITECT c8000 ed AEROSET. Valutazione delle performance analitiche secondo le raccomandazioni NKDEP.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/CreatinineAACC.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-multigent-creatinine-enzymatic-liquid-on-the-abbott-clinical-chemistry-systems.aspx</link>
         <pubDate>08/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of SENTINEL CH. Serum Protein Assays on Synchron LX Clinical Chemistry Sistem</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;F. Rota, A. Mezzadra, R. Dioli&lt;/B&gt;&lt;BR&gt;Valutazione delle performance analitiche di alcune Plasmaproteine SENTINEL CH. sull'analizzatore per chimica clinica Beckman Coulter Synchron LX, per massimizzare il carico di lavoro del laboratorio.&lt;BR&gt;(Studio condotto in collaborazione con Beckman Coulter Inc.)&lt;/FONT&gt;
&lt;a href="/upload_doc/news/ProteinSynchronAACC.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-sentinel-ch-serum-protein-assays-on-synchron-lx-clinical-chemistry-sistem.aspx</link>
         <pubDate>08/09/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Automated haemoglobin in faeces collected on cards for screening for colorectal cancer</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;C. G. Fraser, C. M. Matthew, K. McKay, F. A. Carey, R. J. C. Steele&lt;/B&gt;&lt;BR&gt;Analisi immunoturbidimetrica quantitativa dell'emoglobina nelle feci su campioni&amp;nbsp;raccolti mediante un dispositivo innovativo che consente la spedizione del campione anidro&amp;nbsp; tramite servizio postale.&amp;nbsp;Predittività per la presenza o assenza di neoplasia.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/guthaemoglobininfaeces.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/automated-haemoglobin-in-faeces-collected-on-cards-for-screening-for-colorectal-cancer.aspx</link>
         <pubDate>31/05/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of diagnostic accuracy of screening by fecal occult blood testing (FOBT)</title>
         <description>&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;&lt;B&gt;T. Rubeca, S. Rapi, M. Confortini, M. Brogioni, G. Grazzini, M. Zappa, D. Puliti, G. Castiglione, S. Ciatto&lt;BR&gt;&lt;/B&gt;&lt;/FONT&gt;&lt;FONT face=verdana color=#666666&gt;Valutazione dell'accuratezza diagnostica per il test del sangue occulto nelle feci. Comparazione tra il FOB Gold (Sentinel) e l'OC Sensor (Eiken), metodi immunoturbidimetrici quantitativi oggi disponibili&amp;nbsp;per lo screening di massa per il tumore al colon-retto.&lt;/FONT&gt;&lt;/FONT&gt;
&lt;a href="/upload_doc/news/jbmfobt.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-diagnostic-accuracy-of-screening-by-fecal-occult-blood-testing-fobt.aspx</link>
         <pubDate>31/05/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of the new CK-MB Liquid assay on the ABBOTT Clinical Chemistry Systems</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;R. Lucini, F. Magro, F. Rota, M. Fritz, H. Troonen&lt;/b&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Applicazione del test CK-MB Liquid della SENTINEL CH. sugli analizzatori per chimica clinica ABBOTT ARCHITECT cSystems e AEROSET. Valutazione delle performance analitiche e della variabilità biologica secondo Ricos.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/newCK-MB.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-the-new-ck-mb-liquid-assay-on-the-abbott-clinical-chemistry-systems.aspx</link>
         <pubDate>29/05/2008</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Evaluation of RAMP Whole Blood Analyzer for Point of Care - Troponin I and NT-proBNP Testing</title>
         <description>&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;&lt;B&gt;M.L. Zucker, G.Soffiati, G.Secco, G. Arthur, A. Fortunato&lt;BR&gt;&lt;BR&gt;&lt;/B&gt;Correlazione dei test&amp;nbsp; TnI&amp;nbsp;e NT-proBNP eseguiti su RAMP con il sistema ADVIA Centaur&amp;nbsp;(&amp;nbsp;&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;Siemens Medical Diagnostic Solutions&amp;nbsp;) e con il sistema&amp;nbsp; Elecsys ( Roche Diagnostics ).&lt;BR&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;&lt;BR&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size=1&gt;&lt;FONT face=verdana color=#666666&gt;Poster al&amp;nbsp;10° Annual SCPC Congress - Nashville, TN - April, 2007.&lt;/FONT&gt;&lt;/FONT&gt;
&lt;a href="/upload_doc/news/RAMP_April2007.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/evaluation-of-ramp-whole-blood-analyzer-for-point-of-care-troponin-i-and-nt-probnp-testing.aspx</link>
         <pubDate>27/06/2007</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>VALUTAZIONE  DI  UN NUOVO METODO DIRETTO IN TOTALE AUTOMAZIONE DELLA  EMOGLOBINA  A1c</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;M.Tagliazucchi, A.Fortuna, W.Tizzanini, C.Bitella, R.Sansottera, A.Carbonieri&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Determinazione dell'emoglobina glicata con metodologia&amp;nbsp;immunoturbidimetrica diretta al lattice.&lt;BR&gt;Il nuovo metodo permette di operare direttamente con sangue intero, grazie all' esecuzione della lisi degli eritrociti a bordo dell'analizzatore in automatico.&lt;BR&gt;Determinazione diretta dell' HbA1c con risultato espresso direttamente in percentuale, senza la contemporanea misura dell'emoglobina totale.&lt;BR&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=Verdana color=#666666 size=1&gt;Poster presentato al 39° Congresso Nazionale SIBioC&amp;nbsp;- Rimini - 2/5 Ottobre 2007.&lt;BR&gt;&lt;/FONT&gt;
&lt;a href="/upload_doc/news/HbA1c_SIBIOC_2007.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/valutazione-di-un-nuovo-metodo-diretto-in-totale-automazione-della-emoglobina-a1c.aspx</link>
         <pubDate>10/03/2007</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr.ssa Luigia Paterna - A.O. San Carlo Borromeo, Milano&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Il FOB nella routine di laboratorio; dalla manualità alla automazione.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr.ssa Luigia Paterna 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr. Gianpiero Lollo - USSL 7 Conegliano e Vittorio Veneto, Treviso&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Risultati dello screening del CCR nel territorio della USSL 7.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr. Gianpiero Lollo 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr. Oscar Cabianca - USSL 7 Conegliano e Vittorio Veneto, Treviso&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;La ricerca del Sangue Occulto nelle feci.&lt;BR&gt;L'esperienza del CCR dell'USSL 7 di Conegliano Veneto.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr. Oscar Cabianca 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr. Donato Angioli - USSL 8 Arezzo&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Lo screening del CCR nella ASL 8 di Arezzo, risultati del 1° e del 2° passaggio con la collaborazione del Medico di medicina generale.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr. Donato Angioli 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr. Stefani Rapi - A.O.U. Careggi, Firenze&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;I test ad alta automazione disponibili per lo screening del CCR.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr. Stefano Rapi 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;b&gt;Dr.ssa Tiziana Rubeca - SCPO Firenze&lt;/b&gt;&lt;/FONT&gt;&lt;br&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Il test del Sangue Occulto nell'ambito dello screening del carcinoma colorettale: studi di confronto.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr.ssa Tiziana Rubeca 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Atti del Seminario - Firenze 20-04-2006: La Ricerca del Sangue Occulto nelle Feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;&lt;B&gt;Dr.ssa Grazia Grazzini - CSPO Firenze&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT face=verdana color=#666666 size=1&gt;Lo Screening del carcinoma colon-retto: evidenze scientifiche e attivazione di programmi organizzati in Italia&lt;/FONT&gt;
&lt;a href="/upload_doc/news/Dr.ssa Grazia Grazzini 20_04_06.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/atti-del-seminario-firenze-20-04-2006-la-ricerca-del-sangue-occulto-nelle-feci.aspx</link>
         <pubDate>26/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>Hemoglobin Direct Latex Kit - Specs &amp; Facts</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;Il kit Hemoglobin A1c direct Latex è un metodo immunoturbidimetrico amplificato al lattice per la determinazione in automazione dell'HbA1c nel sangue umano. Questo innovativo metodo consente di dtereminare direttamente l'HbA1c in percentuale con gli analizzatori automatici di chimica clinica di routine utilizzando un singolo canale analitico. Conseguentemente, un ulteriore canale analitico per la determinazione della Emoglobina Totale non è necessario. Alcuni analizzatori di chimica clinica da routine possono essere programmati per eseguire automaticamente la lisi a bordo (on-board). In questo caso, l'intera procedura analitica è completamente automatizzata.&lt;BR&gt;Questo metodo utilizza una interazione antigene-anticorpo per determinare direttamente l'HbA1c in percentuale nel sangue umano. THb e HbA1c hanno la stessa velocità di absorbimento con le particelle aspecifiche di lattice. Ciò costituisce la prima delle reazioni che avviene, quando il campione è miscelato con l'R1. Quando l'anticorpo monoclonale di topo anti-HbA1c umana (R2) è aggiunto, l'immunocomplesso latex - HbA1c - anticorpo monoclonale di topo anti HbA1c umana si forma congiuntamente alla agglutinazione dovuta alla presenza nell'R2 dell'anticorpo monoclonale anti IgG di topo. L'intensità della agglutinazione è misurata in assorbanza. Il valore della concentrazione dell'HbA1c in percentuale è ottenuto interpolando il valore sulla curva di calibrazione eseguita in precedente al test. L'anticorpo anti-HbA1c umana impiegato in questo metodo lega specificatamente il sito 2-Deossifruttosio-valina dell'HbA1c&lt;/FONT&gt;.
&lt;a href="/upload_doc/news/HbA1c_Specs_Facts_IT.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/hemoglobin-direct-latex-kit-specs-facts.aspx</link>
         <pubDate>06/04/2006</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>STUDY OF SAMPLE-TO-SAMPLE AND REAGENT-TO-REAGENT ON AEROSET® END ARCHITECT®</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;Modern random access analysers are playing a determining role in the productivity of clinical laboratories and their ability to offer clinicians an ever-wider range of tests with state-ofthe-art analytical performance. Assay sensitivity increasing and the number of on-board reagents expanding, however, the potential for interaction among and between samples, reagents and analyzer has increased, hence, the possibility for a negative impact on patient results. We here report on our brief to verify sample-tosample and reagent-to-reagent carry over for a total of 32 new reagents equating 32 x (31+ 54) x 2 or 5440 reagent combinations on the Abbott AEROSET® with confirmation of carry over on ARCHITECT® c8000 clinical chemisty analyzers.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/STUDY OF SAMPLE-TO-SAMPLE AND REAGENT-TO-REAGENT.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/study-of-sample-to-sample-and-reagent-to-reagent-on-aeroset-end-architect.aspx</link>
         <pubDate>05/12/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>FOB GOLD - Metodo immunologico per la determinazione della emoglobina occulta nelle feci</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;Il carcinoma colon-rettale è una delle neoplasie più frequenti per incidenza e mortalità. Ogni anno si manifestano più di 1 milione di nuovi casi nel mondo e 34.000 nuovi casi in Italia ed il 90% dei casi si manifesta nella popolazione con oltre 55 anni. Studi epidemiologici hanno dimostrato che nel 85% dei casi non vi è incidenza familiare e solo il 15% dei casi ha una base ereditaria. Il tempo di trasformazione di polipi a cancro è stato stimato in 10-12 anni. In questo scenario si sono sviluoppate delle strategie di pevenzione rivolte alla popolazione con età maggiore di 50-55 anni. La ricerca del Sangue Occulto nelle Feci (Fecal Occult Blood - FOB) da sempre si è rivelata la metodologia più vantaggiosa a disposizione del mondo scientifico per la sua facilità di esecuzione e l'elevata collaborazione da parte dei pazienti.&lt;BR&gt;FOB Gold di Sentinel è l'unico prodotto che consente la determinazione immunologica dell'emoglobina umana nelle feci in completa automazione utilizzando il tubo di raccolta direttamente sugli analizzatori di chimica clinica.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/FOB_GOLD_BROCH_9_2005_b.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/fob-gold-metodo-immunologico-per-la-determinazione-della-emoglobina-occulta-nelle-feci.aspx</link>
         <pubDate>15/09/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>CRP Vario – An Immunoassay for Ultrasensitive and Wide-Range Assay of CRP on AEROSET® and ARCHITECT®</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;C-Reactive Protein (CRP) is the best-known among the acute-phase proteins. CRP concentration increase in response to inflammation, postoperative conditions or tissue damage. CRP normally present in low concentration (&amp;lt; 5 mg/L) can raise rapidly during the acute inflammatory process with values up to 500 mg/L during bacterial infections. In recent years, studies have shown that in apparently healthy individuals a direct correlation between the level of CRP and the risk of developing coronary heart disease (CHD) exists.&lt;BR&gt;CRP has also been reported as a potential marker for monitoring Statin therapy. The various clinical applications of CRP require access to both a sensitive and a wide range assay.&lt;BR&gt;CRP Vario was designed to fulfill both requirements.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/CRP Vario An Immunoassay for Ultrasens &amp; Wide-Range Assay of CRP on AEROSET® &amp; ARCHITECT®.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/crp-vario-an-immunoassay-for-ultrasensitive-and-wide-range-assay-of-crp-on-aeroset-and-architect.aspx</link>
         <pubDate>05/07/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>COMMUTABILITY OF 17 SENTINEL REAGENTS FOR USE ON AEROSET® AND ARCHITECT®</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;Depending on the individual clinicallaboratory needs it is common practice for instrument manufacturers to offer the choice of more than one analyser. These instruments can be entirely different or more often belong to the same family, differing only in terms of capacity and specific performance characteristics.&lt;BR&gt;The goal of this study was to evaluate equivalency of the AEROSET® and ARCHITECT® c8000 (Abbott). Using a validation protocol created for this specific purpose we have compared the performance of 17 IVD products (Sentinel CH, Milan, Italy) on the 2 instruments with regard to precision, accuracy and cross-interference.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/COMMUTABILITY OF 17 SENTINEL REAGENTS FOR USE ON AEROSET® AND ARCHITECT®.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/commutability-of-17-sentinel-reagents-for-use-on-aeroset-and-architect.aspx</link>
         <pubDate>12/05/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>EXPANSION OF ABBOTT ANALYZERS REAGENT MENU: VALIDATION OF 17 SENTINEL REAGENTS</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;New tests previously performed using alternative methods (e.g. Atomic Absorption, Nephelometry, Potentiometry) on different instruments, the necessity for clinical laboratories to overhaul and improve their services in terms of turnaround time, breadth and depth of test menu, quality of results, and in general new value added, together with dwindling economic resources and the availability of high-throughput random-access analysers integrating in-line immunochemistry testing modules have significantly changed the nature of laboratory work. Work is no longer strictly partitioned between diagnostic areas and an increasing number of lab activities are being merged. &lt;/FONT&gt;&lt;FONT face=verdana color=#666666 size=1&gt;To address this challenge Sentinel and Abbott’s scientific and technical work teams have joined forces. We here report on the outcome of this collaboration for the optimisation of 17 in-vitro diagnostic products (Sentinel) and their validation for routine use of the Abbott AEROSET® and ARCHITECT® c8000 analysers according to the requirements of the European Directive 98/79/CE.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/EXPANSION OF ABBOTT ANALYZERS REAGENT MENU VALIDATION OF 17 SENTINEL REAGENTS.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/expansion-of-abbott-analyzers-reagent-menu-validation-of-17-sentinel-reagents.aspx</link>
         <pubDate>12/05/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
      <item>
         <title>CRP VARIO IMPLEMENTS VARIABLE RANGE MEASUREMENT OF C-REACTIVE PROTEIN ON AEROSET® &amp; ARCHITECT® c8000</title>
         <description>&lt;FONT face=verdana color=#666666 size=1&gt;C-Reactive Protein (CRP) is the bestknown among the acute-phase proteins, the concentration of which increases in response to inflammation, postoperative conditions or tissue damage. CRP is normally present in low concentration (&amp;lt;5 mg/L) but increases rapidly during the acute inflammatory process with values increasing up to 500 mg/L during bacterial infections. The level of CRP can be detected 6 hours after inflammation starts reaching a peak at 48 hours. The determination of CRP represents a useful laboratory test for the detection of acute infection and for monitoring of inflammation in acute rheumatic and gastrointestinal diseases. In recent years, studies have shown that in apparently healthy individuals a direct correlation between the level of CRP and the risk of developing coronary heart disease (CHD) exists. CRP has also been reported as a potential marker for monitoring Statin therapy.&lt;/FONT&gt;
&lt;a href="/upload_doc/news/CRP VARIO IMPLEMENTS VARIABLE RANGE MEASUREMENT OF C-REACTIVE PROTEIN.pdf" target="_blank"&gt;&amp;#8226; Download attachment&lt;/a&gt;</description>
         <link>/it/area-scientifica/pubblicazioni/crp-vario-implements-variable-range-measurement-of-c-reactive-protein-on-aeroset-architect-c8000.aspx</link>
         <pubDate>12/05/2005</pubDate>
         <author>Sentinel Diagnostics</author>
      </item>
   </channel>
</rss>
